Carbon-Fibers-Free Anti Static ESD Vinyl Flooring for Hospitals and Laboratories Yhe 2101A-4

Product Details
Customization: Available
After-sales Service: 10 Years
Warranty: 10 Years
Still deciding? Get samples of US$ 13/Square Meter
Request Sample
Manufacturer/Factory, Trading Company, Group Corporation

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5800000 RMB
Plant Area
>2000 square meters
  • Carbon-Fibers-Free Anti Static ESD Vinyl Flooring for Hospitals and Laboratories Yhe 2101A-4
  • Carbon-Fibers-Free Anti Static ESD Vinyl Flooring for Hospitals and Laboratories Yhe 2101A-4
  • Carbon-Fibers-Free Anti Static ESD Vinyl Flooring for Hospitals and Laboratories Yhe 2101A-4
  • Carbon-Fibers-Free Anti Static ESD Vinyl Flooring for Hospitals and Laboratories Yhe 2101A-4
  • Carbon-Fibers-Free Anti Static ESD Vinyl Flooring for Hospitals and Laboratories Yhe 2101A-4
  • Carbon-Fibers-Free Anti Static ESD Vinyl Flooring for Hospitals and Laboratories Yhe 2101A-4
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Features
  • Product Parameters
  • Our Advantages
  • Installation Instructions
  • Packaging & Shipping
  • Certifications
Overview

Basic Info.

Model NO.
YHE-2101A
Material
PVC
Size
1560 mm*15 M
Function
Fireproof, Soundproof, Waterproof, Anti-static, Anti-Bacterial
Surface Treatment
PUD
Color
Various or Customized
Metal Type
Oxidized Metal
Certification
SGS
Usage
Electrical Factory
Advantage
Long Life of Usage
Customized
Customized
Thickness
2 mm /2.5 mm /3 mm
Static Dissipative Electronic Resistance
1.0X10e06-1.0X10e09
Conductive Electronic Resistance
1.0X10e05-1.0X10e08
Starting Voltage
< 100 V
Antimicrobial Activity
>99.9%
Weight
3100g
Wear Resistance
< 0.020g/Cm 2; T Class
Fire Resistance
F V -0
Transport Package
by Sea
Specification
Oxidized Metal
Trademark
YUHE
Origin
China
HS Code
391810
Production Capacity
1, 500, 000square Meter/Year

Product Description

Product Description

 

Carbon-Fibers-Free Anti Static ESD Vinyl Flooring for Hospitals and Laboratories Yhe 2101A-4
Carbon-fibers-free electrostatic discharge(ESD) flooring uses oxidized metal materials instead of traditional carbon black to achieve conductivity and dissipation.

Designed for reliable ESD control, with a consistent and safe discharge rate (10^5 to 10^8 ohms).

Use oxidized metal instead of carbon for conductivity and dissipation. Free from carbon fiber, completely homogeneous, overall anti-static not partially anti-static, reducing the risk of environmental contamination.

Meanwhile,  the properties of oxidized metal protect against microbial growth, its anti-bacterial, antiviral, and antifungal.

Automatic Wax Release Technology requires no waxing for at least 5-8 years, reducing maintenance costs and effort.

YH Floors's Carbon-Fibers ESD Flooring could be used in Clean rooms, Aerospace, Defense R&D, Wind Tunnels, Optics, Robots, Pharmaceutical Factories, Intelligent Upgrades of Traditional Manufacturers, and anywhere flammable & combustible or static-sensitive components.


 
Detailed Photos

Different color options

Carbon-Fibers-Free Anti Static ESD Vinyl Flooring for Hospitals and Laboratories Yhe 2101A-4
More choices

Carbon-Fibers-Free Anti Static ESD Vinyl Flooring for Hospitals and Laboratories Yhe 2101A-4
Different design

Carbon-Fibers-Free Anti Static ESD Vinyl Flooring for Hospitals and Laboratories Yhe 2101A-4
Size

Item
Data
 
Dimensions
1560mmx15m
 
2000mmx15m
Thickness
2.0mm
 
2.5mm
3.0mm
Weight
3100g/m2(2mm)
 
3870g/m2(2.5mm
4650g/m2(3mm)
 
Features

 

* Homogeneous

* No dead or hot spots

* Absence of carbon sloughing

* Overall anti-static no partial anti-static

* No risk of carbon dust particulate contamination

* No carbon chips on the top, clean and good visual

* Anti-bacterial,anti-viral,anti-fungal

* T class wear resistance

* Good flexibility, folding back and forth without breaking or creaking

* Longer service life

* Scratch-resistant, easy to keep clean

* Automatic wax release technology

* No extra wax for at least 5 years
Carbon-Fibers-Free Anti Static ESD Vinyl Flooring for Hospitals and Laboratories Yhe 2101A-4
 
Product Parameters
Carbon fibers free ESD tiles test result
Item Standard DATA
Electrical Resistance(Ω) GJB3007-2009 Conductive1.0×10E05-1.0×10E08ohms
Dissipative1.0×10E06-1.0×10E09ohms
Starting Voltage SJ/T10694-2006 <100V
Static Decry(s) SJ/T10694-2006 <=1s
Wear Resistance(1000r) SJ/T11236-2001 <0.020g/cm2
Fire Resistance SJ/T11236-2001 FV-0
 
Our Advantages

Carbon-Fibers-Free Anti Static ESD Vinyl Flooring for Hospitals and Laboratories Yhe 2101A-4

Long-Term ESD Control:
The floor is uniformly anti-static, offering complete protection across the entire surface, with no hot or dead spots.

NON Particulate Contamination: 
Use oxidized metal instead of carbon for conductivity and dissipation.
Free from carbon fiber, reducing the risk of environmental contamination and offering low emissions for a healthier workspace.


Excellent Antibacterial Properties:
The properties of oxidized metal protect against microbial growth. Its antibacterial, antiviral, and antifungal properties promote cleaner and healthier spaces, making it a more professional choice for the pharmaceutical and biological industries.

Improved Air Quality:
The flooring emits minimal volatile organic compounds (VOCs). It contributes to better indoor air quality and low TVOC emissions, making it a safer choice for indoor environments, especially in sensitive areas like healthcare or cleanrooms.

Exceptional Durability:
The oxidized metal integrated with PVC, is homogeneous, achieving T-class wear resistance, rating, and scratch resistance, the flooring will last for years, even under demanding conditions.

Easy to Install and Maintain:
The flexibility and ease of installation reduce downtime, and the low-maintenance design ensures a hassle-free experience for facility managers.

Cost-Effective:
Automatic Wax Release Technology requires no waxing for at least five years, reducing maintenance costs and effort.
With long-lasting wear resistance, no waxing needed for 5 years, and minimal maintenance, this flooring offers great value for money
.
 
Square meter Professional worker WAX Each time Total
1000m2 $25~75 $1~3 $1000~3000  $34400~36800
5000m2 $25~75 $1~3 $5000~15000  $172000~184000

Final Cost Range

Depending on whether you use the lower ($1/m²) or higher ($3/m²) estimates for waxing and preparation, the annual cost can vary:

  • Low estimate:
  • (1+1)$/m2×1,000m2×8=16,000$
  • (1+1)$/m2×1,000m2×8=16,000$.
  • High estimate:
  • (3+3)$/m2×1,000m2×8=48,000$
  • (3+3)$/m2×1,000m2×8=48,000$.

Labor cost per job=(Hourly rate×Hours)×Number of workers

  • Low estimate: (25×6)×2=300$
  • High estimate: (75×6)×2=900$
Total cost per job=Waxing/preparation cost+Labor cost
  • Waxing/preparation cost (from earlier): $4,000 per job.
  • Low estimate (labor included): 4,000+300=4,300
  • High estimate (labor included): 4,000+900=4,900

Ordinary anti-static floors need to be re-waxed every 45 days on average, about 8 times a year, which requires a lot of post-maintenance costs. To wax anti-static flooring for 1,000m2, the average cost is between $1 to $3 per square meter ($0.09 to $0.28 per square foot). Additional costs may include labor ($25 to $75 per hour per worker) and floor preparation (cleaning or patching), which can add $1 to $3 per square meter. Other factors that influence cost include the frequency of waxing (more frequent re-waxing can increase long-term costs) and the condition of the floor. 

Final Annual Cost Estimate:
Including labor, the total annual cost ranges from
$34,400 to $39,200. For a mid-range estimate,  could achieve around $36,800 per year.

YH FLOORS' S Carbon-Fibers-Free ESD Vinyl Flooring could save you lots of money.

Carbon-Fibers-Free Anti Static ESD Vinyl Flooring for Hospitals and Laboratories Yhe 2101A-4

 
Installation Instructions

 


Carbon-Fibers-Free Anti Static ESD Vinyl Flooring for Hospitals and Laboratories Yhe 2101A-4


Site environment requirements before construction

1. Before the construction of PVC anti-static coiled materials, it must be ensured that the ceiling and walls above the construction site have been completed and that no debris falls from above to damage the floor or coiled materials.

2. Ensure that a grounding point is pre-buried every 300m2.

3. The construction site is equipped with lighting and a 220v power supply and has been powered on.

4. The site is well ventilated and the temperature is between 8ºC and 35ºC

Requirements for the on-site foundation (rough) floor

1. Visually observe that the floor has no sand, cracks, oil stains, and no hollows when knocked.

2. The ground is flat and the unevenness is ≤2mm/2m

3. The floor is dry and the moisture content is ≤4.5%

4. The cement mortar hardness of the floor is ≥1.5Mpa

5. The bottom foundation floor has a waterproof and moisture-proof layer.

Packaging & Shipping

Carbon-Fibers-Free Anti Static ESD Vinyl Flooring for Hospitals and Laboratories Yhe 2101A-4
Accessories
 
Description
Specification
Packing
Welding Rod
4mmØx100m
20rolls/ctn
Copper Foil
0.025 (T)x15mm
(W)x500m
5000m/ctn
Conductive
Adhesive
20kgs/barrel
20kgs/barrel
Certifications

 

Carbon-Fibers-Free Anti Static ESD Vinyl Flooring for Hospitals and Laboratories Yhe 2101A-4
Carbon-Fibers-Free Anti Static ESD Vinyl Flooring for Hospitals and Laboratories Yhe 2101A-4

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier