• ESD Conductive Vinyl Flooring Tiles Carbon-Fibres Loaded Anti Static Flooring
  • ESD Conductive Vinyl Flooring Tiles Carbon-Fibres Loaded Anti Static Flooring
  • ESD Conductive Vinyl Flooring Tiles Carbon-Fibres Loaded Anti Static Flooring
  • ESD Conductive Vinyl Flooring Tiles Carbon-Fibres Loaded Anti Static Flooring
  • ESD Conductive Vinyl Flooring Tiles Carbon-Fibres Loaded Anti Static Flooring
  • ESD Conductive Vinyl Flooring Tiles Carbon-Fibres Loaded Anti Static Flooring

ESD Conductive Vinyl Flooring Tiles Carbon-Fibres Loaded Anti Static Flooring

After-sales Service: 10 Years
Warranty: 10 Years
Material: PVC
Size: 600X600mm, 610X610mm, 900X900mm
Function: Anti-Fouling, Fireproof, Soundproof, Waterproof, Anti-static
Surface Treatment: Homogeneous
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Group Corporation
  • Overview
  • Product Description
  • Product Parameters
  • Our Advantages
  • Packaging & Shipping
  • Certifications
Overview

Basic Info.

Model NO.
YHE-1801
Color
Various or Customized
Metal Type
None
Certification
CE, ISO, ASTM, Floorscore, Tvoc, RoHS, Reach, SGS
Usage
Electrical Factory, Computer Room, Cleanroom, Semiconductor Manufacturing
Advantage
100% Virgin PVC
Customized
Customized
Thickness
2mm, 2.5mm, 3mm
Composition of Material
Homogeneous
Static Conductive Electronic Resistance
1.0X10e4-1.0X10e6 Ohms
Static Dissipative Electronic Resistance
1.0X10e6 Ohms - 1.0X10e9 Ohms
Weight
3800 G/Sqm(2mm), 4800 G/Sqm(2.5mm), 5550g/Sqm(3mm)
Starting Voltage
50V for Conductive, 100V for Dissipative
Walking Body Voltage
Average 30V
Static Decay Time(S)
0.01 Second
Dimensional Stability
0.05%
Wear Resistance
Group P
Slip Resistance Wet
R9
Fire Resistance
Class I; Bfl - S1
Color Fastness
>=6
Residual Identation
0.01mm
Tvoc After 28 Days (Ug/M3)
<10 Ug/M3
Transport Package
Pallet
Specification
12′′x12′′, 24′′x24′′, 36′′x36′′
Trademark
YUHE
Origin
China
HS Code
39181090
Production Capacity
5, 000, 000 Sqm/Year

Product Description

Product Description

Brief Introduction


Electrostatic Discharge (ESD) flooring, also known as anti-static flooring, or static control flooring, comes with permanent anti-static performance (static conductive or static dissipative) and protects electronics from damage caused by static electricity.

The ESD flooring tiles are of high density, homogeneous, and non-porous natural organic tile visual. They're manufactured by an extrusion process, mixing and pressing the 100% virgin PVC granules with carbon (graphite) fibers,
calcium carbonates, DOPT plasticizer, Titanium dioxide white paint, etc. under proper pressure and temperature. Conductive elements are distributed throughout the flooring material (homogeneous), Thus they give ESD floors electrical conductivity, create an electrical pathway from the walking surface to the ground, and guarantee a permanent ESD performance.

ESD vinyl flooring tiles are the choice of professionals for controlling electrostatic discharge in clean rooms, electronics manufacturing, computer rooms, repair facilities, or anywhere static-sensitive components are being used or manufactured.


ESD Tile Sizes

The popular and standard sizes are 600×600mm, 610x610mm, and 900×900mm.

The thickness of the tiles are 2.0mm, 2.5mm, and 3.0mm.

Weight: 3800 g/sqm(2mm), 4800 g/sqm(2.5mm), 5550 g/sqm(3mm).



Features
 
Low TVOC emissions

Meet FloorScore®


DOTP plasticizer, Phthalate FREE

Permanent anti-static properties

Outstanding abrasion, scratch, stain, water, chemical, fire, skid, and light resistance

High durability, easy to clean and maintain

Excellent dimension stability

Antibacterial and fungicidal

Various patterns and colors

Can be seamlessly installed by heat welding

 
Product Parameters

 

Item Standard YH FLOORS Result
Electrical Resistance(Ω) SJ/T11236-2020
EN1081
Conductive  Dissipative 
1.0x10E4 - 1.0x10E6 ohms 1.0x10E6 - 1.0x10E9 ohms
Starting Voltage AATCC-134 50 V 100 V
Static Electrical Propensity EN 1815 Antistatic (≤ 2 KV)
Walking Body Voltage (V) ANSI /ESD S20.20-2021
|U|<100V
Average: 30V
Static Decay(s) Federal Test Method
1018 Method  4046
0.01 sec 0.01 sec
Dimensional Stability(%) after exposure to heat ISO 23999-2018 0.05%
Wear Resistance(1000r) EN 660-2 Group P
Slip Resistance Wet DIN 51130 R9
Fire Resistance ASTM E648-17 Class I
EN13501-1 Bfl - s1
Smoke Density ASTM E 662 < 450
Residual Indentation(mm) ISO 24343-1:2012 0.01mm
Color Fastness ISO 105-B02 ≥ 6
Critical Radiant Flux ASTM E648/NFPA 253 Class 1(> 0.45 W/cm2)
Resistance to Staining & Chemicals EN ISO26987:2012 Not affected, Index 0.
Thermal Conductivity ISO 10456 (EN 12524) 0.25 W/(m.K)
TVOC After 28 Days(μg/m³) ISO 16000-3 < 10 μg/m³
 
Our Advantages

* Leading OEM Service provider in the ESD Vinyl Flooring Industry.

* The largest ESD vinyl flooring manufacturer in China, with over 30 years of experience.


The Annual output is around 5 million sqm for ESD tiles and 7.5 million for ESD sheets.
 

* Quality is among the top 3 in China.

* Completed a lot of ESD vinyl flooring projects for Fortune Global 500 companies in China.

* ISO9001, ISO14001, and ISO45001 certified.

* A full set of SGS certifications of TVOC, RoHS, REACH, and other properties.

ESD vinyl tiles are very flexible because the 100% virgin PVC percentage is 30%, and the DOTP plasticizer percentage is 20%.

There are no excessive shading variations.


 
1. Advanced Manufacturing
Full-automated production lines to ensure higher production capacity and efficiency.

The longest-tempering production lines in China.

Our specialized and unique manufacturing process gives our ESD vinyl flooring tiles the qualities that make them durable, practical, and economical.


 
2. Good-quality environmental-friendly raw material

Sustainability:100% virgin PVC, 100% Recyclable, Contains No Recycled Content.

We use DOTP as a plasticizer for ESD PVC flooring.
.

Dioctyl terephthalate commonly abbreviated DOTP or DEHT. It is a non-phthalate plasticizer that is considered safer than ortho-phthalate plasticizers due to its excellent toxicological profile.

The product does not contain carcinogens such as benzene and heavy metals such as lead. 


 
3. R & D Strength
Patents in products: ESD flooring tiles and anti-static flooring sheets, as well as conductive vinyl flooring production process optimization.

An independent testing laboratory with appropriate testing instruments and equipment.

Testing and calibration are performed using USA/EU/JAPAN/CHINA standard methods. The ESD vinyl flooring tiles are in compliance with different standards.
 
We implement a pretty good color and size management solution.
Packaging & Shipping

 

ESD Conductive Vinyl Flooring Tiles Carbon-Fibres Loaded Anti Static Flooring
 
Certifications

 

ESD Conductive Vinyl Flooring Tiles Carbon-Fibres Loaded Anti Static Flooring

ESD Conductive Vinyl Flooring Tiles Carbon-Fibres Loaded Anti Static Flooring

 

ESD Conductive Vinyl Flooring Tiles Carbon-Fibres Loaded Anti Static Flooring


Tips
1. Blend materials from several cartons to ensure consistent appearance and color or shade variation. 

2. Material is directionally sensitive; shading will occur if directional markings are not followed.
If material is installed with the directional arrows in different directions, it can be corrected utilizing restoration
 maintenance procedures.


3. Easily buffs to a shine, no finishes required, and resists the effects of common chemicals and solder. 

4. The anti-static PVC floor tile is designed, manufactured, and tested to perform at constant temperatures, not fluctuating more than 10° from normal selected service temperatures from the allowable 65° F (19° C) - 85° F (30° C) range.

5. This static conductive ESD vinyl tile is designed for service within ambient relative humidity between 40% and 60%.

6. Sustainability:100% Recyclable, Meets FloorScore, Contains No Recycled Content.

7. During acclimation, the site must be fully enclosed, and weather-tight, and the 
material must be in the installation area with the HVAC system functional and operating at desired service temperatures and maintain an ambient relative humidity between 40% and 60% for a period of 48 hours prior to installation, during the installation and for the service life of the installation afterward.

8. Accessories
Welding rods/welding beads: 4mmØx100m, 20 rolls/ctn
Copper foil/copper strip/copper tape: 0.025 (T)x12mm (W)x100m, 5000m/ctn
Conductive adhesive: 20kg/EA


ESD Conductive Vinyl Flooring Tiles Carbon-Fibres Loaded Anti Static Flooring

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now