ESD Electrostatic Conductive Flooring Tiles in Vinyl Green 600mm

Product Details
Customization: Available
After-sales Service: 10 Years
Warranty: 10 Years
Still deciding? Get samples of US$ 0/Piece
Request Sample
Manufacturer/Factory, Trading Company, Group Corporation

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5800000 RMB
Plant Area
>2000 square meters
  • ESD Electrostatic Conductive Flooring Tiles in Vinyl Green 600mm
  • ESD Electrostatic Conductive Flooring Tiles in Vinyl Green 600mm
  • ESD Electrostatic Conductive Flooring Tiles in Vinyl Green 600mm
  • ESD Electrostatic Conductive Flooring Tiles in Vinyl Green 600mm
  • ESD Electrostatic Conductive Flooring Tiles in Vinyl Green 600mm
  • ESD Electrostatic Conductive Flooring Tiles in Vinyl Green 600mm
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Our Advantages
  • Packaging & Shipping
  • Certifications
Overview

Basic Info.

Model NO.
YHE-1809
Material
PVC
Size
600X600mm, 610X610mm, 900X900mm
Function
Anti-Fouling, Fireproof, Soundproof, Anti-static
Surface Treatment
Simple Color
Color
Green
Metal Type
None
Certification
CE, ISO, Floorscore, SGS, Tvoc, RoHS, Reach
Usage
Electrical Factory, Computer Room, Bank, Offices, Operating Rooms, Data Centers
Advantage
100% Virgin PVC
Customized
Customized
Thickness
2mm, 2.5mm, 3mm
Conductive Electronic Resistance
1.0X10e4-1.0X10e6 Ohms
Static Dissipative Electronic Resistance
1.0X10e6 Ohms - 1.0X10e9 Ohms
Weight
3800 G/Sqm(2mm), 4800 G/Sqm(2.5mm), 5550 G/Sq(3mm)
Starting Voltage
50V for Conductive, 100V for Dissipative
Walking Body Voltage
Average 30V
Static Decay Time(S)
0.01 Second
Dimensional Stability
0.05%
Wear Resistance
Group P
Slip Resistance Wet
R9
Fire Resistance
Class I; Bfl - S1
Color Fastness
>=6
Residual Identation
0.01mm
Composition of Material
Homogeneous
Tvoc After 28 Days (Ug/M3)
<10 Ug/M3
Transport Package
by Sea
Specification
12′′x12′′, 24′′x24′′, 36′′x36′′
Trademark
YUHE
Origin
China
HS Code
391810
Production Capacity
5, 000, 000 Sqm/Year

Product Description

Product Description

Brief Introduction

Electrostatic Discharge (ESD) flooring, also known as anti-static flooring, or static control flooring, comes with permanent anti-static performance (static-dissipative or conductive) and protects electronics from damage caused by static electricity.

The ESD flooring tiles are of high density, homogeneous, and non-porous natural organic tile visual. They're manufactured by an extrusion process, mixing and pressing the 100% virgin PVC granules with carbon (graphite) fibers,
calcium carbonates, DOPT plasticizer, Titanium dioxide white paint, etc. under proper pressure and temperature. Conductive elements are distributed throughout the flooring material (homogeneous), Thus they give ESD floors electrical conductivity, create an electrical pathway from the walking surface to the ground, and guarantee a permanent ESD performance.

ESD vinyl flooring tiles are the choice of professionals for controlling electrostatic discharge in clean rooms, electronics manufacturing, computer rooms, repair facilities, or anywhere static-sensitive components are being used or manufactured.


ESD Tile Sizes

The popular and standard size is 600×600mm, 610x610mm, and 900×900mm.

The thickness of the tiles is 2.0mm, 2.5mm, and 3.0mm.

Weight: 3800g/m2(2mm), 4800g/m2(2.5mm), 5550g/m2(3mm)



Features
 
Low TVOC emissions

Meet FloorScore®


DOTP plasticizer, Phthalate FREE

Permanent anti-static properties

Outstanding abrasion, scratch, stain, water, chemical, fire, skid, and light resistance

High durability, easy to clean and maintain

Excellent dimension stability

Antibacterial and fungicidal

Various patterns and colors

Wear resistance reaches P class in all ESD vinyl flooring series. 

Can be seamlessly installed by heat welding

Lifetime electrical resistance warranty
Product Parameters

Technical data

Item Standard YH FLOORS Result
Electrical Resistance(Ω) SJ/T11236-2020
EN1081
Conductive  Dissipative 
1.0x10E4 - 1.0x10E6 ohms 1.0x10E6 - 1.0x10E9 ohms
Starting Voltage AATCC-134 50 V 100 V
Static Electrical Propensity EN 1815 Antistatic (≤ 2 KV)
Walking Body Voltage (V) ANSI /ESD S20.20-2021
|U|<100V
Average: 30V
Static Decay(s) Federal Test Method
1018 Method  4046
0.01 sec 0.01 sec
Dimensional Stability(%) after exposure to heat ISO 23999-2018 0.05%
Wear Resistance(1000r) EN 660-2 Group P
Slip Resistance Wet DIN 51130 R9
Fire Resistance ASTM E648-17 Class I
EN13501-1 Bfl - s1
Smoke Density ASTM E 662 < 450
Residual Indentation(mm) ISO 24343-1:2012 0.01mm
Color Fastness ISO 105-B02 ≥ 6
Critical Radiant Flux ASTM E648/NFPA 253 Class 1(> 0.45 W/cm2)
Resistance to Staining & Chemicals EN ISO26987:2012 Not affected, Index 0.
Thermal Conductivity ISO 10456 (EN 12524) 0.25 W/(m.K)
TVOC After 28 Days(μg/m³) ISO 16000-3 < 10 μg/m³
 
Our Advantages

 

* Leading OEM Service provider in ESD Vinyl Flooring Industry.
* The largest ESD vinyl flooring manufacturer in China, with over 20 years of experience.

The Annual output is around 5 million sqm for ESD tiles and 7.5 million for ESD sheets. 
* Quality is among the top 3 in China.

* Completed a lot of ESD vinyl flooring projects for Fortune Global 500 companies in China.
* ISO9001, ISO14001, and ISO45001 certified.

* A full set of SGS certifications of TVOC, RoHS, and other properties contributing to good indoor air quality (IAQ)  for durable and sustainable static vinyl flooring tiles.

ESD vinyl tiles are very flexible because the 100% virgin PVC percentage is 30%, and the DOTP plasticizer percentage is 20%.

There're no excessive shading variations.

ESD vinyl flooring tiles are of very good flexibility.
 
1. Advanced Manufacturing
Full-automated production lines to ensure higher production capacity and efficiency.

The longest-tempering production lines in China to control dimensional stability effectively.

Our specialized and unique manufacturing process gives our ESD vinyl flooring tiles the qualities that make them durable, practical, and economical.


 
2. Good-quality environmental-friendly raw material

Sustainability:100% virgin PVC, 100% Recyclable, Meets FloorScore, Contains No Recycled Content.

We use DOTP plasticizer for ESD PVC flooring.
Dioctyl terephthalate commonly abbreviated DOTP or DEHT. It is a non-phthalate plasticizer that is considered safer than ortho-phthalate plasticizers due to its excellent toxicological profile.

The product does not contain carcinogens such as benzene and heavy metals such as lead. 
And it's of low TVOC emission.
 
3. R & D Strength
Patents in production process optimization.

An independent testing laboratory with appropriate testing instruments and equipment.

Testing and calibration are performed using USA/EU/JAPAN/CHINA standard methods. So we can produce ESD vinyl flooring products in compliance with different standards.
 
We implement a pretty good color and size management solution.
 
Packaging & Shipping

 

ESD Electrostatic Conductive Flooring Tiles in Vinyl Green 600mm
Certifications

 

ESD Electrostatic Conductive Flooring Tiles in Vinyl Green 600mm

ESD Electrostatic Conductive Flooring Tiles in Vinyl Green 600mm

 

ESD Electrostatic Conductive Flooring Tiles in Vinyl Green 600mm

   Tips
1. Blend materials from several cartons to ensure consistent appearance and color or shade variation. 

2. Material is directionally sensitive; shading will occur if directional markings are not followed.
If material is installed with the directional arrows in different directions, it can be corrected utilizing restoration
 maintenance procedures.


3. Easily buffs to a shine, no finishes required, and resists the effects of common chemicals and solder. 

4. The anti-static PVC floor tile is designed, manufactured, and tested to perform at constant temperatures, not fluctuating more than 10° from normal selected service temperatures from the allowable 65° F (19° C) - 85° F (30° C) range.

5. This static conductive ESD vinyl tile is designed for service within ambient relative humidity between 40% and 60%.

6. Sustainability:100% Recyclable, Meets FloorScore, Contains No Recycled Content.

7. During acclimation, the site must be fully enclosed, and weather-tight, and the 
material must be in the installation area with the HVAC system functional and operating at desired service temperatures and maintain an ambient relative humidity between 40% and 60% for a period of 48 hours prior to installation, during the installation and for the service life of the installation afterward.

8. Accessories
Welding rods/welding beads: 4mmØx100m, 20 rolls/ctn
Copper foil/copper strip/copper tape: 0.025 (T)x12mm (W)x100m, 5000m/ctn
Conductive adhesive: 20kg/EA


ESD Electrostatic Conductive Flooring Tiles in Vinyl Green 600mm

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier